Daikin Error Codes: What They Mean & What to Do [2026]

Updated 28 November 2026 · By the Alpha & Omega Air Store team, Authorised Daikin Specialist Dealer since 1989

A Daikin error code is a two-character fault code that tells a technician which part of the system has a problem.

On most Daikin wireless remotes, hold the timer cancel button for five seconds while pointing it at the unit to display the code.

The most searched code, U4, means a communication fault between the indoor and outdoor units. Most codes need a licensed technician.

The letter shows the area of the fault and the second character narrows it down. A codes usually relate to the indoor unit, E, F, H, J and L codes to the outdoor unit and compressor, and U codes to power, refrigerant or communication.

The code tells you what the unit detected, not always why. This guide lists the codes that apply to Daikin split systems, using Daikin's own descriptions, and sets out what you can safely check before booking a service.

In this guide

How do you check a Daikin error code?

Point the remote at the indoor unit and hold the timer cancel button for five seconds. On many models the code then appears in the temperature display with a long beep. On others, "00" flashes and you keep pressing timer cancel until you hear a continuous beep; the code shown at that point is the fault. Hold the button for five seconds again to exit.

That procedure comes from Daikin's ARC447A remote manual. Daikin Malaysia's service page describes the same "00" method. Some older remotes use a different button combination, so check your model's manual if nothing happens. The display clears itself after about a minute without a button press.

Ducted systems with a wired wall controller usually show the code directly on the controller's screen, so you don't need a button sequence. Note the code exactly as shown, including whether it's a zero or the letter O.

Daikin Cora split system indoor unit whose wireless remote can display error codes
On a Daikin split system, the error code shows on the remote's temperature display, not on the indoor unit itself.

What do the most common Daikin error codes mean?

The codes owners search for most are U4 (indoor to outdoor communication fault), A5 (high pressure control in heating or freeze-up protection in cooling), U0 (shortage of refrigerant), A1 (indoor circuit board fault), A6 (indoor fan motor fault) and E7 (outdoor fan motor fault). All except a one-off A5 need a technician.

Code Daikin's description In plain English What to do
U4 Malfunction of transmission between indoor and outdoor unit The two units have stopped talking to each other Restart once at the isolator; call a technician if it returns
A5 High pressure control in heating, freeze-up protection control in cooling The unit protected itself from pressure or icing Clean the filter and check nothing blocks the vents; call if it returns
U0 Shortage of refrigerant Refrigerant is low, often from a leak Licensed technician only
A1 Malfunction of indoor unit PCB Indoor circuit board fault Technician
A6 Fan motor locked, overload, overcurrent Indoor fan isn't turning properly Technician
E7 Malfunction of outdoor unit fan motor Outdoor fan problem Check nothing is jammed in the outdoor fan guard from outside; then a technician
U2 Defect of power supply voltage or instantaneous power failure Power dipped or dropped out Often clears after a storm or outage; call an electrician or technician if it repeats

Descriptions are quoted from Daikin's official error code tool (Room Air category). The plain-English column and suggested actions are our guidance.

What does Daikin error code U4 mean?

U4 means "malfunction of transmission between indoor and outdoor unit", according to Daikin. The indoor unit has lost communication with the outdoor unit, so the system stops to protect itself. Causes include a power interruption, damaged or loose wiring between the units, or a circuit board fault. A single restart sometimes clears it; a U4 that keeps coming back needs a technician.

It can appear after a storm, a blackout or electrical work on the house, when a power interruption has upset communication between the units. Try this once:

  1. Turn the air conditioner off with the remote.
  2. Switch it off at the isolator or circuit breaker and leave it off for a few minutes.
  3. Switch it back on and start the unit.

If U4 comes back, stop there. Checking the interconnecting cable and circuit boards involves live electrical parts and is a job for a licensed technician. If the breaker itself keeps tripping, don't keep resetting it. Daikin Malaysia's service page warns against resetting a tripped breaker without first having the equipment's insulation checked.

Full list of Daikin split system error codes

Daikin's error code tool lists these codes for its room air conditioners, meaning wall-mounted split systems. The first letter groups the fault: A for indoor unit faults, C for indoor sensors, E, F, H, J, L and P for the outdoor unit and compressor, and U for power, refrigerant and communication. Codes relating to humidifier units only apply to models that have one.

Code Daikin's description
A1 Malfunction of indoor unit PCB
A3 Malfunction of drain level control system
A5 High pressure control in heating, freeze-up protection control in cooling
A6 Fan motor locked, overload, overcurrent
AH Malfunction of dust collector of air cleaner
C4 Malfunction of liquid pipe thermistor for heat exchanger
C5 Malfunction of gas pipe thermistor for heat exchanger
C7 Front panel driving motor fault
C9 Malfunction of suction air thermistor
CC Malfunction of humidity sensor system
E5 Overheat of inverter compressor motor
E7 Malfunction of outdoor unit fan motor
E8 Overcurrent of inverter compressor
E9 Malfunction of electronic expansion valve coil
EA Malfunction of four way valve
F3 Malfunction of discharge pipe temperature
H0 Malfunction of sensor system of compressor
H3 Malfunction of high pressure switch (HPS)
H5 Malfunction of compressor motor overload thermistor
H6 Malfunction of position detection sensor
H8 Malfunction of compressor input (CT) system
H9 Malfunction of outdoor air thermistor
J3 Malfunction of discharge pipe thermistor
J5 Malfunction of suction pipe thermistor
J6 Malfunction of heat exchanger thermistor
L3 Electrical box temperature rise
L4 Malfunction of inverter radiating fin temperature rise
L5 Inverter instantaneous overcurrent (DC)
LC Malfunction of transmission between outdoor unit PCB and micro-computer
P4 Malfunction of radiating fin temperature sensor
U0 Shortage of refrigerant
U2 Defect of power supply voltage or instantaneous power failure
U4 Malfunction of transmission between indoor and outdoor unit
U5 Malfunction of transmission between indoor unit and remote controller
UA Defect of indoor/outdoor power supply

Source: Daikin error code search tool, Room Air category. Code lists vary between models and generations, so if your code isn't here, check your unit's manual or give us a call. Ducted and commercial systems use some different codes.

What can you safely do yourself?

You can note the code, clean the filter, clear anything blocking the indoor vents or outdoor unit, and restart the system once at the isolator. That resolves some A5, U2 and one-off U4 codes. Don't open either unit, don't keep resetting a tripping breaker, and never attempt anything involving refrigerant, which legally requires a licensed technician.

  1. Write down the exact code, plus your model number from the sticker on the side of the indoor unit. A technician can often diagnose faster with both.
  2. Clean the filter. Restricted airflow can trigger protection codes such as A5. Our guide to cleaning your air conditioner filter takes about 15 minutes.
  3. Check the outdoor unit for leaves, branches or anything stopping the fan or blocking airflow. Look only; don't reach inside the fan guard.
  4. Restart once at the isolator, leaving it off for a few minutes.
  5. If the code returns, book a service. Running a unit with a recurring fault can turn a small repair into a bigger one.

If the code appears alongside water dripping from the indoor unit, also read our guide to an aircon leaking water. A3, for example, is Daikin's code for a drain level fault.

Is the repair covered by warranty?

If your Daikin is within its warranty period, contact Daikin or your installer before anyone else works on it. New Daikin split systems sold in Australia carry a 5-year parts and labour warranty, provided the unit was bought from an authorised source and installed by a licensed technician. Repairs by someone else can complicate a warranty claim.

Keep your proof of purchase and installation paperwork somewhere you can find them. As an Authorised Daikin Specialist Dealer, every Daikin unit we supply comes with the full Daikin Australia warranty.

Repair or replace?

Repair is usually the right call for a unit under about 10 years old with a one-off fault. Consider replacing if the unit is 10 to 15 years old or older and the fault involves the compressor, a refrigerant leak or a main circuit board, or if it keeps throwing codes after repairs. Newer inverter units also run more efficiently than older models.

If you're replacing a Daikin, these are the current residential models we stock, all reverse cycle with the full Daikin warranty. Our Daikin split system guide compares them in detail.

Daikin Cora Series split system air conditioner
Best All-Rounder | Authorised Daikin Dealer
Daikin Cora Series

Australia's most popular Daikin. 2kW to 7.1kW, R-32, Intelligent Eye sensor and enzyme filter. 5-year Daikin warranty.

From $1,262.33 Shop Daikin Cora →
Daikin Alira X split system with Streamer air purification
Built-In Wi-Fi | Authorised Daikin Dealer
Daikin Alira X

Streamer air purification, built-in Wi-Fi and Coanda airflow. 2kW to 7.1kW, white or black.

From $1,179.05 Shop Daikin Alira X →
Daikin Lite Series split system air conditioner
Entry-Level Daikin | Authorised Daikin Dealer
Daikin Lite Series

Daikin reliability at the lowest Daikin price. 2kW to 7.1kW with the same 5-year warranty.

From $1,139.84 Shop Daikin Lite →

Frequently asked questions

How do I reset a Daikin error code?

Turn the unit off with the remote, switch it off at the isolator or breaker for a few minutes, then turn it back on. This clears the code from the display, but it doesn't fix the fault. If the same code returns, the underlying problem is still there and needs a technician.

Why is my Daikin air conditioner flashing?

A flashing operation lamp on the indoor unit usually means the unit has detected a fault and stopped. Use the remote to display the error code, note it down, then try one restart at the isolator. If the lamp keeps flashing, book a service.

What does U0 mean on a Daikin?

Daikin describes U0 as "shortage of refrigerant". The system has detected low refrigerant, usually because of a leak. Topping up without finding and fixing the leak only delays the problem, and any refrigerant work must be done by a licensed technician.

What does A5 mean on a Daikin air conditioner?

Daikin describes A5 as "high pressure control in heating, freeze-up protection control in cooling". The unit has protected itself from excessive pressure or icing. Clean the filter, make sure the vents aren't blocked, and restart once. If A5 returns, call a technician.

Can I keep using my Daikin with an error code?

Usually the unit stops itself when it shows a fault, and you shouldn't force it to keep running. A one-off code that clears after a restart and doesn't return is generally fine. A recurring code means something needs fixing, and continued use can make the repair bigger.